Fresh Air + Purification + Energy Recovery + Dehumidification + Temperature Control

 

With the rapid development of the global commodity economy in recent years, air pollution has become increasingly concerning. Air quality in big cities is continuously deteriorating, with haze occurring in various places. People are constantly suffering from pharyngitis, pneumonia, and lung cancer.

 

Unfortunately, indoor condition might not be any better than outdoors. Indoor pollution can be five times that of outdoor. Total volatile organic compounds (TVOC) can be the most important polluting gas in indoor air. Most of these gases are emitted from furniture or decoration materials, and even from the building itself. In order to remove these polluting gases, many families hire air treatment companies to treat them. But in fact, these air management companies are treating the symptoms rather than the root cause, thus unable to completely solve the problem. These gases will be released slowly with changes in temperature and humidity, even for more than ten years. At best, the air treatment company can only remove the existing polluted air. After a period of time, the room will continue to be filled with these polluting gases, causing threats to the human body.

 

The quality of the home environment is the most direct manifestation of our quality of life. Creating the most healthy and comfortable indoor air environment is the most essential embodiment of our goal: To provide clean, temperature and humidity- controlled fresh air with energy recovery system in everyone’s home. More and more people are beginning to pay attention to products related to their own health; among those, air purification products are particularly prominent. Air-related equipment have become an indispensable household appliance in our pursuit of higher quality of life. Therefore, LUKO FORTESVO ensures to quickly respond to market needs and provide highly competitive prices and performance. Our excellent product enables the following outcomes: Fresh Air + Purification + Energy Recovery + Dehumidification + Temperature Control – A Comfort Air System. The system uses a patented Internet of Things technology to intelligently manage and record the air condition of the home.

World Health Organization’s new standards for residential health

According to the World Health Organization (WHO), residential health standards and national requirements for green and energy-saving buildings, health is defined as “being physically, mentally, and socially in good condition, rather than simply referring to illness or weakness.” According to this definition, a “healthy house” refers to a house that can result in occupants to be physically, mentally, and socially in good condition.

 

Creating Your Ideal Home

Explore the future with healthy housing standards:

 

  • Low concentration of chemicals that can cause allergies.
  • To meet the requirements of the first point, avoid using wall or renovation materials that easily emit harmful chemicals.
  • Equipped with well-performing ventilation equipment, especially in sealed buildings, a central ventilation system must
    be used to discharge indoor air.
  • Local exhaust equipment should be installed in the kitchen or smoking area.
  • Living room, bedroom, kitchen, toilet, corridor, bathroom, etc. should be kept at 20°C – 26°C throughout the year.
  • Humidity is maintained at 40%-65% throughout the year.
  • Concentration of carbon dioxide should be lower than 1000PPMo
  • Concentration of suspending dust should be less than 0.15mg square meter.
  • Noise level should be less than 50 decibels.
  • Daylight for more than 3 hours a day.
  • Lighting equipment are well set up for sufficient brightness.
  • The house has sufficient resistance to natural disasters.
  • Sufficient building area per capita to ensure privacy. A good residence should conveniently accommodate the elderly and the disabled.

 

Multiple Air Protection Layers

 

  1. Dust, particulates, dander and pollen are the causes of allergies, eye diseases and skin diseases.
  2. Microorganisms including insects affects skin health. Highly harmful fungi such as mites and worms may cause respiratory diseases.
  3. Highly harmful microorganisms like influenza virus, mold contains causes high fever, diarrhea, pneumonia and other diseases.
  4. Hazardous waste gas: Vehicles, industries, and cigarettes are the main causes of headaches, soreness and dizziness.

 

MODEL

FD-EX, Fresh Air Ventilation Dehumidifier

with ERV and Inverter Compressor

 

LUKO, FD-EX series is uniquely patented design, cater for fresh air dehumidification with Energy Recovery Ventilation system. The system is based on a two-way air flow mechanism, where there is exchange of heat between fresh air and exhaust air. The energy recovery module efficiently absorbs and releases heat to ensure sufficient heat exchange between the air.

 

Once the fresh air is partially cooled, it will then pass through the dehumidification system where the air will be purified with G4 Pre-Filter, F7 Secondary Filter and H13 high efficiency HEPA filter. The purified and dry comfortable fresh air will then be supplied into the treated room. Simultaneously, the humid and smelly indoor air will be exhausted and replaced with a fresh treated air.

 

The unit is built with energy efficiency in mind, to provide comfortable fresh air for the indoors. This equipment is designed to effectively handle airflows in naturally hot or cold weather. This unit includes a direct expansion cooling system and a full heat exchange system for energy recovery and replacement of exhaust by fresh air that meets the requirements of the modern standards.

Key Features:

  • Fully automated fresh air dehumidification with easy installation
  • Positive air pressure to drain out condensate water. Our machine is designed with a unique way that the airflow of the system will help to push the condensate water out from the drain pan
  • High heat exchange efficiency, the product adopts advanced counter-current structure design, which can greatly improve heat exchange efficiency
  • Equipped with EC Fan with variable fan speed which auto adjusts for different air volume based on indoor CO2 level
  • Evaporator with internal thread pipe, help to increase efficiency. Comes with SUS304 stainless steel drain pan
  • 5-Stages of Air Filtration System (Primary, Secondary, HEPA, Ionizer, UV lamp)
  • Filled with environmentally friendly refrigerant of R410A or R134A using Panasonic compressor
  • Intelligent controller with multiple functions to control the operation of the dehumidifier
  • Two-way ventilation, supply of fresh air and exhaust of indoor contaminated air, can achieve positive pressure operation according to customer requirements Built-in Cross Flow Energy Recovery Ventilator (ERV), which helps to reduce the energy required for treating the fresh air, thus achieving high efficiency and energy saving goals

 

MODEL FD-EX80L FD-EX100L
Dehumidifying Capacity @ 27 celcius, 60% RH 80 liter / day 100 liter / day
Fresh Air Flow Rate 720 / 510 / 400 m3/h 930 / 660 / 530 m3 /h
Exhaust Air Flow Rate 610 / 420 / 340 m3 /h 300 / 560 / 450 m3/h
Energy Recovery Ventilator Efficiency

≥ 55 ~ 60%

≥ 55 ~ 60%

Fresh Air Ventilator Rated Power 680W / 3.1A 820W / 3.7A
Dehumidifying Rated Power

2510W / 11.3A

3150W / 14.2A
Dehumidifying Air Flow Rate

800 – 960 m3/h

 1100 – 1280 m3/h
Fan Type

EC Type with Variable Speed Control

Fan Static Pressure 180 PA
Noise Level

≤ 45DB

Compressor Panasonic Inverter
Refrigerant R410A
Expansion Valve Electronic Expansion Valve
Power Requirement 230V / 1PH / 50Hz
Heat Exchanger Copper Tube with Aluminium Coil
Drain Pan Made of 304 Stainless Steel
Drainage Positive Pressure Draginage / DN20 (Drain Hole Size)

FD-ZF, Fresh Air Ventilation Temperature Control Dehumidifier

with Inverter Compressor

Key Features:

  • Fully automated fresh air dehumidification and cooling system with easy installation
  • Built-in dehumidification coil and condensation heat recovery coil enables the air supply temperature to be adjustable from
    8 to 22 degrees.
  • With fresh air condition (35 ̊C, 60%/30 ̊C, 80%), the supply air condition can have absolute humidity up to 7g/kg, dew point
    <10 ̊C.
  • Evaporator with internal thread pipe, help to increase efficiency. Comes with SUS304 stainless steel drain pan
  • Filled with environmentally friendly refrigerant of R410A or R134A using Panasonic compressor
  • Intelligent controller with multiple functions to control the operation of the dehumidifier
  • Two-way ventilation, supply of fresh air and exhaust of indoor contaminated air, can achieve positive pressure
    operation according to customer requirements
  • Independent dehumidification and cooling systems to meet the indoor load demand, making the whole system to have lower energy consumption.
  • Built-in EC fan, with external static pressure > 150Pa, meeting the demand of low-level air supply.
  • Primary Filter G4 + Secondary Filter F7 + HEPA Filter H13 can be aligned with the exhaust fan.

Model FD-ZF350 FD-ZF550 FD-ZF750 FD-ZF10000
Dehumidifying Capacity 90 Liter / Day 140 Liter / Day 190 Liter / Day 250 Liter / Day
Fresh Air Flow Rate (m3/h) 175/0 275/0 375/0 500/0
Return Air Flow Rate (m3/h) 175/350 275/550 375/750 500/1000
Supply Air Flow Rate (m3/h) 350 550 750 10000
Rated Dehumidifying Power 1720 W/7.8 A 2600 W/12 A 3150 W/14.2 A 3540 W/16 A
Rated Cooling Capacity 5200 W 7750 W 10000 W 12000 W
Rated Heating Capacity 5400 W 8080 W 12000 W 13500 W
Size (mm) 1260*799*320 1260*799*320 1260*839*320 1260*839*320
Fan Static Pressure 150 Pa 150 Pa 200 Pa 250 Pa
Noise Level ≤ 45DB ≤ 45DB ≤ 45DB ≤ 55DB
Fan Type EC Type with Variable Speed Control
Compressor Panasonic Inverter (Low Temperature System)
Refrigerant R410A
Expansion Valve Electronic Expansion Valve
Power Requirement 220V / 1PH / 50Hz
Drain Pan Made of 304 Stainless Steel
Drainage Positive Pressure Drainage / DN20 (Drain Hole Size)
Return Inlet Sensor 5 In 1 Multi-Functional Sensor

 

  • Rated Cooling Capacity based on outdoor dry bulb temperature 35 ̊C, wet bulb temperature 28 ̊C, indoor dry bulb temperature 27 ̊C, RH 60%.
  • Rated Heating Capacity based on outdoor dry bulb temperature 7 ̊C, wet bulb temperature 6 ̊C, indoor dry bulb temperature 20 ̊C, wet bulb temperature 15 ̊C.
  • Technical specification and dimensions are subject to change without prior notice